Home > Emergency & OR Equipment > Respirators / Ventilators > Portable ventilator YSAV-H602

Portable ventilator YSAV-H602

The machine is suitable for adults and children, microcomputer control, LCD display
  • Model: YSAV-H602
  • Price: Inquiry
  • Goods click count:782
  • 销量:最近售出 1868
  • Rank:: (已有0条评论)
  • gifts for buying:0 Integral
  • MOQ:1
  • Ship From:China Guangdong Guangzhou
  • Shipping: 10-15 working days after receiving payment
Quantity: -+

Product details

Shipping methods

Payment methods

Portable ventilator YSAV-H602 

Portable ventilator YSAV-H602


The machine is suitable for adults and children, microcomputer control, LCD display, pneumatic electronic control ventilator, light touch key to set working parameters, pressure light column to monitor airway pressure at any time, the machine can be used with or without electricity, with lithium battery, if the battery is exhausted, it can control breathing manually.It is necessary equipment for family, field, emergency vehicle and emergency room.

 

1. Breathing mode:

Synchronous (A / C), forced (IPPV), manual

2. Air circuit performance:

Inspiratory oxygen concentration: 45%, 100%

3. Ventilation performance:

a) Respiratory rate: 6-60 times / min, continuously adjustable.

b) Synchronous inspiratory time: 0.2-2s, continuously adjustable.

c) Tidal volume: 100-1000ml, continuously adjustable.

d) The ratio of suction and respiration: 1:1, 1:2, 1:3, 1:4, 1:5, 2:1, 2:3, 3:5, continuously adjustable.

4. Alarm performance:

a) Pressure upper limit alarm: 2-6kpa, continuously adjustable.

b) Pressure lower limit alarm: 0  2KPa, continuously adjustable.

c) Battery under voltage alarm: audible and visual alarm.

d) Mute: no less than 2min.

5. Monitoring performance:

a) Tidal volume.b) Respiratory rate.c) Respiratory ratio D) synchronization time

6. Overall performance:

a) Power supply: AC 220V ± 22V 50Hz ± 1Hz

Built in lithium 7.2V power supply battery

b) Host power: 25VA.

c) Electrical safety: meet the relevant requirements of GB9706.1-2007 medical electrical equipment Part I: General requirements for safety for type II B application part of equipment.

7. Service conditions: 

a) Ambient temperature: + 5 ℃ ~ + 40 ℃.

b) Relative humidity: 30% - 75%.

c) Atmospheric pressure: 96-104kpa.

d) Use air source: oxygen 0.25-0.3mpa.

8. Storage and transportation:

The normal storage and transportation temperature range of the product is - 18 ℃ ~ + 50 ℃, the relative humidity range is 15% ~ 95%, and the atmospheric pressure range is 70kpa ~ 110kpa. There is no corrosive gas and well ventilated place. During the transportation, it should be moisture-proof, handle with care, and pay attention to the direction sign

Portable ventilator YSAV-H602 Portable ventilator YSAV-H602


Coronavirus Use Portable ICU Ventilator YSAV-100C Coronavirus Use Portable ICU Ventilator YSAV-100C Coronavirus Use Portable ICU Ventilator YSAV-100C Coronavirus Use Portable ICU Ventilator YSAV-100C

 


Previous: Moible Ventilator YSAV310A
Next: Portable ICU Ventilator YSAV-100C
Shipping methods
Payment methods
Get Price
Write down your demand below and we will contact you within 24h!
Your Name: *
Company Name: *
Address: *
Email: *
Phone: *
Contents: *
Code: captcha *